2. Specifications
2 - 18
2-2-4 AC reactor
An AC reactor must be installed for each power supply unit.
(1) Specifications
AC reactor
AC reactor type B-AL- 7.5K 11K 18.5K 30K 37K
Compatible
power
supply unit
type
MDS-C1-CV-
37,55,75 110 150,185 220,260,300 370
Rated capacity
(30-minute rating)
[kW]
7.5 11 18.5 30 37
Rated voltage [V] 200/200 to 230AC
Rated current [A] 27 33 66 110 129
Frequency [Hz] 50/60 Frequency fluctuation within ±3%
Ambient
temperature
Operation: -10 to 60°C (with no freezing),
Storage/Transportation: -10°C to 60°C (with no freezing)
Ambient humidity
Operation: 80%RH or less (with no dew condensation),
Storage/Transportation: 80%RH or less (with no dew condensation)
Atmosphere
Indoors (no direct sunlight)
With no corrosive gas, inflammable gas, oil mist or dust
Altitude
Operation/Storage: 1000 meters or less above sea level,
Transportation: 10000 meters or less above sea level
Environ-
ment
Vibration/impact
9.8m/s2 (1G) / 98m/s2 (10G)
Weight [kg] 3.6 3.0 5.2 6.0 10